Categories: Walk-in Test Chamber
Follow:
| Walk-in Test chamber | |||||||
| Model | JWC8-6085 | JWC12-6085 | JWC20-6085 | JWC30-6085 | JW40-6085 | ||
| Nominal internal volume(m³) | 8m³ | 12m³ | 20m³ | 30m³ | 40m³ | ||
| Performance | Temperature range | Optional range: -60 ℃ (-20 ℃, 40℃, 60℃)~High temperature+85 ℃ (+85 ℃, +120℃, +150 ℃) | |||||
| Temperature range(JWC series only) | 20%~98% R.H. (humidity working range+20 ℃~+85 ℃) | ||||||
| Temperature fluctuation | ≤±0.5 | ||||||
| Temperature uniformity | ≤2℃ | ||||||
| Temperature deviation | ≤±2℃ | ||||||
| Temperature deviation(JWC series only) | -3~+2%R.H.(75%R.H.above), ±5%R.H.(75%R.H.following) | ||||||
| Heating rate(average) | Optional range: 0.5~15 ℃/min, load can be specified | ||||||
| Cooling rate(average) | Optional range: 0.5~15 ℃/min, load can be specified | ||||||
| Remarks | Above indicators are measured in no load at ambient temperature of 20±2°C (According to GB/T 5170.2-2017) | ||||||
| Internal dimensions(mm) | D | 2000 | 3000 | 4000 | 4000 | 5000 | |
| W | 2000 | 2000 | 2500 | 3000 | 3200 | ||
| H | 2000 | 2000 | 2000 | 2500 | 2500 | ||
| External dimensions(mm) | D | 3000 | 3000 | 5000 | 5000 | 6000 | |
| W | 2240 | 2240 | 2740 | 2740 | 2940 | ||
| H | 2320 | 2320 | 2320 | 2820 | 2820 | ||
| Remarks | The above external dimensions do not include unit dimensions. | ||||||
| Test hole | TwoΦ100, On the right side | ||||||
| Using environment temperature | 5-40 ℃ | ||||||
| Shell | Sprayed steel plate | ||||||
| Interior | SUS304 stainless steel | ||||||
| Cooling mode | Air-cooled(water temperature 7~28℃,hydraulic pressure 0.2~0.5Mpa, To ensure cooling performance) | ||||||
| Controller | 10′ Color touch screen Controller | ||||||
| Input | PT100+imported capacitive humidity sensor | ||||||
| Communication function | RS485 or standard RJ45 network interface, standard USB interface | ||||||
| Power supply | 380V+10%/50HZ+1,three-phase-five-wire system (3P+N+G) | ||||||
| Meet the testing method | GB2423.1-2008、GB2423.2-2008、GB2423.3-2008:GB2423.4-2008 GJB150.3-2009、GJB150,4-2009、GJB150.9-2009 | ||||||
| Safety precautions | Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Short circuit protection for heater, refrigeration unit exceeding Voltage/ overload protection; Overload/ overheating protection for blower motor; Control board overcurrent protection and leakage protection, humidification fault protection. | ||||||
| Optional | Special testing holes, slopes, customized temperature rise and fall rates, etc. | ||||||

Copyright © 2024 SICHUAN JUPITER TECHNOLOGY CO.,LTD. All Rights Reserved Privacy Policy