board by the self-made warehouse assembly at the scene, and can provide various size specifications of the products according to the needs of users;
of the science of air flow design, make indoor temperature consistent (wet), avoid any corner;
7 inch LCD touch screen, temperature and humidity control system configuration in Chinese color display screen, a high degree of automation, simple operation;
programming for man-machine dialogue way, even for the first time the user can be barrier-free operation;
wireless alarm system, intelligent mobile phone and the perfect combination of instrument monitoring alarm system;
every product according to customer requirements, to ensure the equipment of applicability and high efficiency, energy saving;
according to need to use air cooled or water-cooled cooling way.
Walk-in Test chamber
Model
JWC8-6085
JWC12-6085
JWC20-6085
JWC30-6085
JW40-6085
Nominal internal volume(m³)
8m³
12m³
20m³
30m³
40m³
Performance
Temperature range
Optional range: -60 ℃ (-20 ℃, 40℃, 60℃)~High temperature+85 ℃ (+85 ℃, +120℃, +150 ℃)
Temperature range(JWC series only)
20%~98% R.H. (humidity working range+20 ℃~+85 ℃)
Temperature fluctuation
≤±0.5
Temperature uniformity
≤2℃
Temperature deviation
≤±2℃
Temperature deviation(JWC series only)
-3~+2%R.H.(75%R.H.above), ±5%R.H.(75%R.H.following)
Heating rate(average)
Optional range: 0.5~15 ℃/min, load can be specified
Cooling rate(average)
Optional range: 0.5~15 ℃/min, load can be specified
Remarks
Above indicators are measured in no load at ambient temperature of 20±2°C
(According to GB/T 5170.2-2017)
Internal dimensions(mm)
D
2000
3000
4000
4000
5000
W
2000
2000
2500
3000
3200
H
2000
2000
2000
2500
2500
External dimensions(mm)
D
3000
3000
5000
5000
6000
W
2240
2240
2740
2740
2940
H
2320
2320
2320
2820
2820
Remarks
The above external dimensions do not include unit dimensions.
Testhole
TwoΦ100, On the right side
Using environment temperature
5-40 ℃
Shell
Sprayed steel plate
Interior
SUS304 stainless steel
Cooling mode
Air-cooled(water temperature 7~28℃,hydraulic pressure 0.2~0.5Mpa,
To ensure cooling performance)
Controller
10′ Color touch screen Controller
Input
PT100+imported capacitive humidity sensor
Communication function
RS485 or standard RJ45 network interface, standard USB interface
Power supply
380V+10%/50HZ+1,three-phase-five-wire system (3P+N+G)
Meet the testing method
GB2423.1-2008、GB2423.2-2008、GB2423.3-2008:GB2423.4-2008
GJB150.3-2009、GJB150,4-2009、GJB150.9-2009
Safety precautions
Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Short circuit protection for heater, refrigeration unit exceeding Voltage/ overload protection; Overload/ overheating protection for blower motor; Control board overcurrent protection and leakage protection, humidification fault protection.
Optional
Special testing holes, slopes, customized temperature rise and fall rates, etc.