For different users and test conditions, we can design and produce different sizesspecial environmental chambers to simulate different environmental conditions.
Introduction
Room, high and low temperature in improving the reliabilityof the at the same time, greatly reduces the power consumption, Using the temperature and humidity control system can realize automationand easy operation and development of new energy saving technology. Operators can into the lab to manipulate the characteristics of the experiment, for aerospace products, industrial products manufacturer in bulk or large parts, semi-finished products, product temperature (wet) provides the degree of environmental test conditions.
Feature
Walk-in Test chamber | |||||||
Model | JWC8-6085 | JWC12-6085 | JWC20-6085 | JWC30-6085 | JW40-6085 | ||
Nominal internal volume(m³) | 8m³ | 12m³ | 20m³ | 30m³ | 40m³ | ||
Performance | Temperature range | Optional range: -60 ℃ (-20 ℃, 40℃, 60℃)~High temperature+85 ℃ (+85 ℃, +120℃, +150 ℃) | |||||
Temperature range(JWC series only) | 20%~98% R.H. (humidity working range+20 ℃~+85 ℃) | ||||||
Temperature fluctuation | ≤±0.5 | ||||||
Temperature uniformity | ≤2℃ | ||||||
Temperature deviation | ≤±2℃ | ||||||
Temperature deviation(JWC series only) | -3~+2%R.H.(75%R.H.above), ±5%R.H.(75%R.H.following) | ||||||
Heating rate(average) | Optional range: 0.5~15 ℃/min, load can be specified | ||||||
Cooling rate(average) | Optional range: 0.5~15 ℃/min, load can be specified | ||||||
Remarks | Above indicators are measured in no load at ambient temperature of 20±2°C (According to GB/T 5170.2-2017) |
||||||
Internal dimensions(mm) | D | 2000 | 3000 | 4000 | 4000 | 5000 | |
W | 2000 | 2000 | 2500 | 3000 | 3200 | ||
H | 2000 | 2000 | 2000 | 2500 | 2500 | ||
External dimensions(mm) | D | 3000 | 3000 | 5000 | 5000 | 6000 | |
W | 2240 | 2240 | 2740 | 2740 | 2940 | ||
H | 2320 | 2320 | 2320 | 2820 | 2820 | ||
Remarks | The above external dimensions do not include unit dimensions. | ||||||
Testhole | TwoΦ100, On the right side | ||||||
Using environment temperature | 5-40 ℃ | ||||||
Shell | Sprayed steel plate | ||||||
Interior | SUS304 stainless steel | ||||||
Cooling mode | Air-cooled(water temperature 7~28℃,hydraulic pressure 0.2~0.5Mpa, To ensure cooling performance) |
||||||
Controller | 10′ Color touch screen Controller | ||||||
Input | PT100+imported capacitive humidity sensor | ||||||
Communication function | RS485 or standard RJ45 network interface, standard USB interface | ||||||
Power supply | 380V+10%/50HZ+1,three-phase-five-wire system (3P+N+G) | ||||||
Meet the testing method | GB2423.1-2008、GB2423.2-2008、GB2423.3-2008:GB2423.4-2008 GJB150.3-2009、GJB150,4-2009、GJB150.9-2009 |
||||||
Safety precautions | Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Short circuit protection for heater, refrigeration unit exceeding Voltage/ overload protection; Overload/ overheating protection for blower motor; Control board overcurrent protection and leakage protection, humidification fault protection. | ||||||
Optional | Special testing holes, slopes, customized temperature rise and fall rates, etc. |