10
10

Walk-in Test chamber

Categories:

For different users and test conditions, we can design and produce different sizes special environmental chambers to simulate different environmental conditions.

Introduction

Room, high and low temperature in improving the reliability of the at the same time, greatly reduces the power consumption, Using the temperature and humidity control system can realize automation and easy operation and development of new energy saving technology. Operators can into the lab to manipulate the characteristics of the experiment, for aerospace products, industrial products manufacturer in bulk or large parts, semi-finished products, product temperature (wet) provides the degree of environmental test conditions.

Feature

  • board by the self-made warehouse assembly at the scene, and can provide various size specifications of the products according to the needs of users;
  • of the science of air flow design, make indoor temperature consistent (wet), avoid any corner;
  • 7 inch LCD touch screen, temperature and humidity control system configuration in Chinese color display screen, a high degree of automation, simple operation;
  • programming for man-machine dialogue way, even for the first time the user can be barrier-free operation;
  • wireless alarm system, intelligent mobile phone and the perfect combination of instrument monitoring alarm system;
  • every product according to customer requirements, to ensure the equipment of applicability and high efficiency, energy saving;
  • according to need to use air cooled or water-cooled cooling way.
Walk-in Test chamber
Model JWC8-6085 JWC12-6085 JWC20-6085 JWC30-6085 JW40-6085
Nominal internal volume(m³) 8m³ 12m³ 20m³ 30m³ 40m³
Performance Temperature range Optional range: -60 ℃ (-20 ℃, 40℃, 60℃)~High temperature+85 ℃ (+85 ℃, +120℃, +150 ℃)
Temperature range(JWC series only) 20%~98% R.H. (humidity working range+20 ℃~+85 ℃)
Temperature fluctuation ≤±0.5
Temperature uniformity ≤2℃
Temperature deviation ≤±2℃
Temperature deviation(JWC series only) -3~+2%R.H.(75%R.H.above), ±5%R.H.(75%R.H.following)
Heating rate(average) Optional range: 0.5~15 ℃/min, load can be specified
Cooling rate(average) Optional range: 0.5~15 ℃/min, load can be specified
Remarks Above indicators are measured in no load at ambient temperature of 20±2°C
(According to GB/T 5170.2-2017)
Internal dimensions(mm) D 2000 3000 4000 4000 5000
W 2000 2000 2500 3000 3200
H 2000 2000 2000 2500 2500
External dimensions(mm) D 3000 3000 5000 5000 6000
W 2240 2240 2740 2740 2940
H 2320 2320 2320 2820 2820
Remarks The above external dimensions do not include unit dimensions.
Test hole TwoΦ100, On the right side
Using environment temperature 5-40 ℃
Shell Sprayed steel plate
Interior SUS304 stainless steel
Cooling mode Air-cooled(water temperature 7~28℃,hydraulic pressure 0.2~0.5Mpa,
To ensure cooling performance)
Controller 10′ Color touch screen Controller
Input PT100+imported capacitive humidity sensor
Communication function RS485 or standard RJ45 network interface, standard USB interface
Power supply 380V+10%/50HZ+1,three-phase-five-wire system (3P+N+G)
Meet the testing method GB2423.1-2008、GB2423.2-2008、GB2423.3-2008:GB2423.4-2008
GJB150.3-2009、GJB150,4-2009、GJB150.9-2009
Safety precautions Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Short circuit protection for heater, refrigeration unit exceeding Voltage/ overload protection; Overload/ overheating protection for blower motor; Control board overcurrent protection and leakage protection, humidification fault protection.
Optional Special testing holes, slopes, customized temperature rise and fall rates, etc.

 

Contact

  • SICHUAN JUPITER TECHNOLOGY CO.,LTD
  • +86 13601818584ly@jupiter-zyp.com
  • Room 207 No. 3699 Gonghexin Road Shanghai China, Shanghai, China
  • Leave message

    Request Inquery