Introduction
Adapted to determine the clean materials, electronics, electrical products, components and military equipment, etc. according to the national standard, military standard requirements when subjected to abrupt changes in the ambient air temperature (temperature shocks) when, whether to generate physical damage or performance degradation.
Feature
Temperature Shock Chamber(Three Chamber) | |||||||||
Model | JTS72F-B/S/E | JTS100F-B/S/E | JTS150F-B/S/E | JTS200F-B/S/E | JTS320F-B/S/E | JTS500F-B/S/E | JTS1000F-B/S/E | ||
Nominal inside volume(L) | 72L | 100L | 150L | 200L | 320L | 500L | 1000L | ||
Performance parameter | Heat storage chamber | Temperature exposure range | +50℃~+150℃ | ||||||
Upper limit of preheating temperature | 200℃ | ||||||||
Heating time | RT~+200℃, B type: ≤50 min; S type: ≤40 min; E type: ≤30 min | ||||||||
Cold storage chamber | Temperature exposure range | B type: 0~-40℃; S type: 0~-55℃; E type: 0~-65℃ | |||||||
Lower limit of pre cooling temperature | -75℃ | ||||||||
Cooling time | RT~-70℃, B type: ≤60 min; S type: ≤50 min; E type: ≤40 min | ||||||||
Chamber | Temperature shock range | B type: -40℃~+150℃; S type: -55℃~+150℃; E type: -65℃~+150℃ | |||||||
Temperature fluctuation | ≤±0.5 | ||||||||
Temperature uniformity | ≤2℃ | ||||||||
Temperature deviation | ≤±2℃ | ||||||||
Transfer time | ≤10s | ||||||||
Temperature recovery time | ≤5min | ||||||||
Load (steel) | 3kg | 5kg | 7kg | 10kg | 15kg | 20kg | 40kg | ||
Optional: High and low temperature test function | Temperature range | -65℃~+150℃ | |||||||
Temperature rise and fall rate | B type nearly 2℃/min, S type nearly 3℃/min, E nearly 4℃/min | ||||||||
Remarks | Above indicators are measured in no load at ambient temperature of 20±2°C(According to GB/T 5170.2-2017) | ||||||||
Internal dimensions | D | 400 | 500 | 500 | 600 | 700 | 800 | 1000 | |
W | 450 | 500 | 600 | 600 | 700 | 900 | 1000 | ||
H | 400 | 400 | 500 | 550 | 650 | 700 | 1000 | ||
External dimensions | D | 2150 | 2300 | 2300 | 2500 | 2600 | 2800 | 3600 | |
W | 1450 | 1500 | 1600 | 1600 | 1700 | 1900 | 2550 | ||
H | 2000 | 2000 | 2200 | 2300 | 2500 | 2620 | 2250 | ||
Caster | 4 -6 standard casters | / | |||||||
Test hole | Φ50 | Φ100 | |||||||
Stainless steel shelf (2 pcs in standard configuration) | Bearing 20kg/pc | Bearing 30kg/pc | Bearing 50kg/pc | ||||||
Using environment temperature | 0~+40℃ | ||||||||
Shell | Sprayed steel plate | ||||||||
Interior | SUS 304 stainless steel | ||||||||
Cooling mode | water-cooling, (water temperature 7~28℃, hydraulic pressure 0.2~0.4Mpa, to ensure cooling performance) | ||||||||
Controller | 7′ Color touch screen Controller | ||||||||
Communication function | RS485 or standard RJ45 network interface, standard USB interface | ||||||||
Installed capacity(kw)(L/S/E) | 13/17/22 | 17/22/29 | 23/28/34 | 27/33/40 | 33/40/50 | 50/60/75 | 75/90/110 | ||
Weight(kg) | 800 | 1300 | 1600 | 1900 | 2500 | 2800 | 3600 | ||
Meet the testing method | GJB150.5-2009, GB/T2423-2008. The optional high and low temperature test function also meets GB2423.1-2008, GB2423.2-2008, GJB150.3-2009, GJB150.4-2009. |
||||||||
Safety precautions | Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Heater short circuit protection, refrigeration unit overpressure/ overload/ oil shortage protection; Humidifier fault protection; Overload/ overheating protection for blower motor, overcurrent protection and leakage protection for control board; Cooling water shortage protection, gas source undervoltage protection, etc. | ||||||||
Optional | 1.Optional high and low temperature testing function; 2. Optional special test holes and special shelves; 3. Optional liquid nitrogen function. |