介绍适应于根据国家标准确定清洁材料、电子、电器产品、元器件和军工装备等,军用标准要求在受到周围空气温度突变(温度冲击)时,是否产生物理损伤或性能下降。特征
    3 cases of equipment is divided into: high temperature, low temperature area, test area, test the product in the test area, impact at high temperature or low temperature zone temperature impact test area, test the product for static type. The touch controller interface, operation easy. Impact mode application wind path switching mode will import test temperature zone, cold and hot shock tests. High temperature shock or the impact of low temperature and maximum time of up to 999 h, the maximum cycle of up to 9999 times. System can make automatic cycle official holding or manual selective shock impact and can be set two areas or areas and cold heat impact and inception. Cooling binary refrigeration system, cooling rapidly, for water-cooled cooling way. Can perform impact test at room temperature to meet the standard and test method: GJB150.5 temperature impact test; GJB360.7 temperature impact test; GB / 2423.22 temperature impact test.
Temperature Shock Chamber(Three Chamber) Model JTS72F-B/S/E JTS100F-B/S/E JTS150F-B/S/E JTS200F-B/S/E JTS320F-B/S/E JTS500F-B/S/E JTS1000F-B/S/E Nominal inside volume(L) 72L 100L 150L 200L 320L 500L 1000L Performance parameter Heat storage chamber Temperature exposure range +50℃~+150℃ Upper limit of preheating temperature 200℃ Heating time RT~+200℃, B type: ≤50 min; S type: ≤40 min; E type: ≤30 min Cold storage chamber Temperature exposure range B type: 0~-40℃; S type: 0~-55℃; E type: 0~-65℃ Lower limit of pre cooling temperature -75℃ Cooling time RT~-70℃, B type: ≤60 min; S type: ≤50 min; E type: ≤40 min Chamber Temperature shock range B type: -40℃~+150℃; S type: -55℃~+150℃; E type: -65℃~+150℃ Temperature fluctuation ≤±0.5 Temperature uniformity ≤2℃ Temperature deviation ≤±2℃ Transfer time ≤10s Temperature recovery time ≤5min Load (steel) 3kg 5kg 7kg 10kg 15kg 20kg 40kg Optional: High and low temperature test function Temperature range -65℃~+150℃ Temperature rise and fall rate B type nearly 2℃/min, S type nearly 3℃/min, E nearly 4℃/min Remarks Above indicators are measured in no load at ambient temperature of 20±2°C(According to GB/T 5170.2-2017) Internal dimensions D 400 500 500 600 700 800 1000 W 450 500 600 600 700 900 1000 H 400 400 500 550 650 700 1000 External dimensions D 2150 2300 2300 2500 2600 2800 3600 W 1450 1500 1600 1600 1700 1900 2550 H 2000 2000 2200 2300 2500 2620 2250 Caster 4 -6 standard casters / Test hole Φ50 Φ100 Stainless steel shelf (2 pcs in standard configuration) Bearing 20kg/pc Bearing 30kg/pc Bearing 50kg/pc Using environment temperature 0~+40℃ Shell Sprayed steel plate Interior SUS 304 stainless steel Cooling mode water-cooling, (water temperature 7~28℃, hydraulic pressure 0.2~0.4Mpa, to ensure cooling performance) Controller 7′ Color touch screen Controller Communication function RS485 or standard RJ45 network interface, standard USB interface Installed capacity(kw)(L/S/E) 13/17/22 17/22/29 23/28/34 27/33/40 33/40/50 50/60/75 75/90/110 Weight(kg) 800 1300 1600 1900 2500 2800 3600 Meet the testing method GJB150.5-2009, GB/T2423-2008. The optional high and low temperature test function also meets GB2423.1-2008, GB2423.2-2008, GJB150.3-2009, GJB150.4-2009. Safety precautions Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Heater short circuit protection, refrigeration unit overpressure/ overload/ oil shortage protection; Humidifier fault protection; Overload/ overheating protection for blower motor, overcurrent protection and leakage protection for control board; Cooling water shortage protection, gas source undervoltage protection, etc. Optional 1.Optional high and low temperature testing function; 2. Optional special test holes and special shelves; 3. Optional liquid nitrogen function.

接触

  • 四川木​​星科技有限公司
  • +86 13601818584ly@jupiter-zyp.com
  • 中国上海共和新路 3699 号 207 室, 上海, 中国
  • 留言

    版权所有 © 2024 四川木星科技有限公司版权所有隐私策略

    信息

    电子邮件

    WhatsApp

    请求查询