IntroductionAdapted to determine the clean materials, electronics, electrical products, components and military equipment, etc. according to the national standard, military standard requirements when subjected to abrupt changes in the ambient air temperature (temperature shocks) when, whether to generate physical damage or performance degradation.Feature
3 cases of equipment is divided into: high temperature, low temperature area, test area, test the product in the test area, impact at high temperature or low temperature zone temperature impact test area, test the product for static type.
The touch controller interface, operation easy.
Impact mode application wind path switching mode will import test temperature zone, cold and hot shock tests.
High temperature shock or the impact of low temperature and maximum time of up to 999 h, the maximum cycle of up to 9999 times.
System can make automatic cycle official holding or manual selective shock impact and can be set two areas or areas and cold heat impact and inception.
Cooling binary refrigeration system, cooling rapidly, for water-cooled cooling way.
Can perform impact test at room temperature to meet the standard and test method: GJB150.5 temperature impact test; GJB360.7 temperature impact test; GB / 2423.22 temperature impact test.
Temperature Shock Chamber(Three Chamber)
Model
JTS72F-B/S/E
JTS100F-B/S/E
JTS150F-B/S/E
JTS200F-B/S/E
JTS320F-B/S/E
JTS500F-B/S/E
JTS1000F-B/S/E
Nominal inside volume(L)
72L
100L
150L
200L
320L
500L
1000L
Performance parameter
Heat storage chamber
Temperature exposure range
+50℃~+150℃
Upper limit of preheating temperature
200℃
Heating time
RT~+200℃, B type: ≤50 min; S type: ≤40 min; E type: ≤30 min
Cold storage chamber
Temperature exposure range
B type: 0~-40℃; S type: 0~-55℃; E type: 0~-65℃
Lower limit of pre cooling temperature
-75℃
Cooling time
RT~-70℃, B type: ≤60 min; S type: ≤50 min; E type: ≤40 min
Chamber
Temperature shock range
B type: -40℃~+150℃; S type: -55℃~+150℃; E type: -65℃~+150℃
Temperature fluctuation
≤±0.5
Temperature uniformity
≤2℃
Temperature deviation
≤±2℃
Transfer time
≤10s
Temperature recovery time
≤5min
Load (steel)
3kg
5kg
7kg
10kg
15kg
20kg
40kg
Optional: High and low temperature test function
Temperature range
-65℃~+150℃
Temperature rise and fall rate
B type nearly 2℃/min, S type nearly 3℃/min, E nearly 4℃/min
Remarks
Above indicators are measured in no load at ambient temperature of 20±2°C(According to GB/T 5170.2-2017)
Internal dimensions
D
400
500
500
600
700
800
1000
W
450
500
600
600
700
900
1000
H
400
400
500
550
650
700
1000
External dimensions
D
2150
2300
2300
2500
2600
2800
3600
W
1450
1500
1600
1600
1700
1900
2550
H
2000
2000
2200
2300
2500
2620
2250
Caster
4 -6 standard casters
/
Test hole
Φ50
Φ100
Stainless steel shelf (2 pcs in standard configuration)
Bearing 20kg/pc
Bearing 30kg/pc
Bearing 50kg/pc
Using environment temperature
0~+40℃
Shell
Sprayed steel plate
Interior
SUS 304 stainless steel
Cooling mode
water-cooling, (water temperature 7~28℃, hydraulic pressure 0.2~0.4Mpa, to ensure cooling performance)
Controller
7′ Color touch screen Controller
Communication function
RS485 or standard RJ45 network interface, standard USB interface
Installed capacity(kw)(L/S/E)
13/17/22
17/22/29
23/28/34
27/33/40
33/40/50
50/60/75
75/90/110
Weight(kg)
800
1300
1600
1900
2500
2800
3600
Meet the testing method
GJB150.5-2009, GB/T2423-2008.
The optional high and low temperature test function also meets GB2423.1-2008, GB2423.2-2008, GJB150.3-2009, GJB150.4-2009.
Safety precautions
Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Heater short circuit protection, refrigeration unit overpressure/ overload/ oil shortage protection; Humidifier fault protection; Overload/ overheating protection for blower motor, overcurrent protection and leakage protection for control board; Cooling water shortage protection, gas source undervoltage protection, etc.
Optional
1.Optional high and low temperature testing function; 2. Optional special test holes and special shelves; 3. Optional liquid nitrogen function.