Introduction
In the field of hydrogen fuel cell technology, the performance and reliability of fuel cells are crucial. In order to ensure the reliability of high-power fuel cell stacks under various environmental conditions, our company has developed the JSW series walk-in hydrogen fuel cell stack environmental test chamber. This series is designed as advanced equipment for fuel cell stacks ranging from 80KW to 300KW, and can conduct environmental simulation tests in accordance with standards such as GB/T 31035-2014.
The experimental module has the ability to simulate the combined effects of various factors such as temperature and humidity in the natural environment. It is closely integrated with the stack test bench in terms of software and hardware systems, and the main control system of the test bench can remotely monitor and control the working status of the test cabin. The temperature and humidity control is very flexible, and can be programmed separately or linked with the main control program of the test bench to ensure the accuracy and controllability of the testing process.
The equipment in the test chamber meets multiple standards, including GB/T 31035-2014, GB/T 20042.2-2008, and GB/T33978-2017, to ensure that your stack testing meets industry requirements.
Solutions
Provide precise climate and environmental testing solutions for hydrogen fuel cell stacks of different powers.
The product is highly targeted and covers the vast majority of large and medium-sized battery stacks on the market.
Integrated design, integrating the required hydrogen air pre cooling system and ethylene glycol circulation system as a supporting solution.
Advanced software and hardware integration ensures close coordination between the environmental testing chamber and the testing bench.
High safety, with a safety matrix linkage reaction strategy to ensure the safe conduct of the experimental process.
JSW Series Walk-in Power Reactor Environmental Test Chamber
Model
JSW-8T
JSW-15T
JSW-24T
Adaptive distribution stack
80KW
120KW
150KW
200KW
250KW
300KW
Hydrogen air pre cooling device
JHAP26-T
JHAP39-T
JHAP412-T
JHAP515-T
JHAP618-T
Internal volume
8m³
15m³
24m³
Internal dimensions
(D*W*H)
2000mm*2000mm*2000mm
2500mm*2500mm*2400mm
3200mm*3000mm*2500mm
External dimensions (D*W*H)
3300mm*2300mm*2700mm
3800mm*2800mm*3100mm
4500mm*3300mm*3200mm
Refrigeration unit size
(D*W*H)
1700mm*1350mm*1700mm
2200mm*1200mm*2000mm
2200mm*1400mm*2000mm
Hydrogen air pre cooling dimensions
(D*W*H)
2250mm*1250mm*2600mm
2400mm*1400mm*2800mm
Pressure relief port size
0.24m³
0.36m³
0.45m³
Installed power
90KW
113KW
155KW
170KW
183KW
Maximum current
135A
180A
248A
278A
304A
Cooling water flow rate
20m³/h
26m³/h
36m³/h
39m³/h
43m³/h
General Technical Indicators
Temperature range
-40℃~90℃
Heating rate
≥ 1 ℃/min (-40 ℃ ~90 ℃ range, average throughout the entire process
when carrying hydrogen fuel cell stacks and fixtures, without generating heat. )
Cooling rate
≥ 1 ℃/min (-40 ℃ ~90 ℃ range, average throughout the entire process,
when carrying hydrogen fuel cell stacks and fixtures, without generating heat.)
Temperature deviation
≤± 2.0 ℃ (unloaded)
Temperature fluctuation
≤ ± 0.5 ℃ (Static without thermal load)
≤± 2.0 ℃ (Dynamic test condition)