Chambre à vide haute-basse température et basse pression

Introduction

High – low temperature and low pressure test chamber is a simulation of high altitude, high altitude, (plateau area) climate for storage and transport reliability test, and can be simultaneously electrified on the test piece for electrical performance parameters of the test equipment. Applicable to the defense industry, aerospace industry automation components, automotive parts, batteries, flat panel display group industry and related products for high temperature, low temperature, height (not higher than 30,000 m above sea level or 45,000 m) and high and low temperature cycling test, temperature and altitude of the integrated test, high and low temperature test this chamber can be used for heat dissipation test specimens and non-heat dissipation test specimen test.

Safety & Protections

Protection contre les sous-tensions, les surtensions, les phases manquantes et les erreurs de séquence de phases ; 3 types de protection contre la surchauffe Protection contre les courts-circuits du chauffage ; Surpression/surcharge/protection du compresseur : Protection contre les défauts de l'humidificateur : Protection contre la surcharge/surchauffe du moteur du ventilateur ; Protection contre les surintensités du panneau, protection contre les fuites à la terre : protection contre les surcharges de la pompe à vide : protection contre la pression inadéquate de l'air comprimé.

Application

Principalement utilisé dans l'aviation, l'aérospatiale, l'information, l'électronique et d'autres domaines pour déterminer l'instrumentation, les produits électroniques, les matériaux, les composants, l'équipement, etc. dans des conditions simples ou simultanées de basse pression, haute température, basse température pour l'adaptabilité environnementale et le test de fiabilité ou les données techniques mesurées des échantillons.

Possibilités

  1. Port de câble spécial ;
  2. Verrouillage électrique, bornes ;
  3. Special shelf
Chambre à vide haute-basse température et basse pression
Modèle JTP250(C) JTP500(C) JTP1000(C) JTP2000(C)
Nominal inside volume(L) 250L 500L 1000L 1000L
Performance Plage de température -40℃~+150℃ for model without suffix C, -70℃~+150℃ for model with suffix C
Fluctuations de température ≤±0.5 (Under atmospheric pressure)
Uniformité de la température ≤2℃
Écart de température ≤±2℃ (Under atmospheric pressure)
Vitesse de chauffage (moyenne) 2 ℃/min 2 ℃/min 2 ℃/min 2 ℃/min
Taux de refroidissement (moyen) 1 ℃/min 1 ℃/min 1 ℃/min 1 ℃/min
Remarques Above indicators are measured in no load at ambient temperature of 20±2°C (According to GB/T 5170.2-2017)
Plage de pression atmosphérique Pression ventriculaire ~ 0,5 kPa
Erreur de pression atmosphérique ±2kPa(≥40kPa), ±5%(2kPa~40kPa), ±0.1kPa(≤2kPa)
Temps de réduction de pression Under atmospheric pressure~1kPa,nearly 30min
Temps de récupération de pression ≤10kPa/min
Dimension interne (mm) D*W*H 550*600*750 700*800*900 1000*1000*1000 1400*1200*1200
Dimension externe (mm) D*W*H 2000*1060*1900 2500*1260*2050 2720*1460*2050 3150*1650*2050
Trou d'essai 1 Φ100 2Φ100
Stainless steel shelf (2 pcs in standard configuration) Roulement 20 kg/pièce Roulement 50 kg/pièce
Utilisation de la température ambiante 0 ~ + 40 ℃
Coquille Sprayed steel plate
Interior Acier inoxydable SUS304
Mode refroidissement water-cooling,(water temperature 7~28℃,hydraulic pressure 0.2~0.4Mpa, To ensure cooling performance)
Contrôleur 7′ Color touch screen Controller
Fonction de communication Interface réseau RS485 ou RJ45 standard, interface USB standard
Source de gaz Crushing air 0.4~0.7MPa
Capacité installée (kw)(-/-C) 14/17 19/24 28/34 33/42
Weight(kg) 1000 2000 3000 4500
Alimentation 380V+10%/50HZ+1, three-phase-five-wire system (3P+N+G)
Découvrez la méthode de test GB2423.1-2008, GB2423.2-2008, GB2423.21-2008, GJB150.3-2009, GJB150.4-2009, GJB150.2-2009 (except for rapid bucking), GJB150.6-2009
Précautions de sécurité Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Short circuit protection for heater refrigerator overpressure/ overload protection; Overload/ overheating protection for blower motor; Control board overcurrent protection and leakage protection, vacuum pump overload protection, compressed air undervoltage protection.
Facultatif Trous de test spéciaux, fiches aviation, terminaux, étagères spéciales, etc., en option avec décompression rapide de 15 s et décompression explosive de 0,1 s

Contact

  • SICHUAN JUPITER TECHNOLOGIE CO., LTD
  • +86 13601818584ly@jupiter-zyp.com
  • Salle 207 n° 3699 Gonghexin Road Shanghai Chine, Shanghai, Chine
  • Laisser un message

    Demander une demande