Introduction
In the field of hydrogen energy, the performance and reliability of fuel cell stacks are crucial. In order to ensure the reliability and stable operation of the fuel cell stack under different environmental conditions, our company has developed the JCH series ammonia fuel cell stack environmental test chamber. This series is an advanced equipment designed specifically for the 1KW 30KW fuel cell stack and can conduct environmental simulation tests in accordance with standards such as GB/24554-2009.
The JCH series test chamber has the ability to simulate the combined effects of various factors such as temperature and humidity in natural environments. It has achieved close integration of software and hardware systems with the test bench, and the main control system of the test bench can remotely monitor and control the working status of the test chamber. The temperature control is flexible and can be individually programmed for control. It can also be coordinated with the main control program of the testing bench to ensure the accuracy and controllability of the testing process.
Solutions
JCH Series Hydrogen Fuel CellStack Environmental Test Chamber | ||||
Model | JCH500-ST | JCH1000-ST | JCH2000-ST | JCH3000-ST |
Stack power | 2KW | 5KW | 10KW | 30KW |
Hydrogen flow rate | 70NLPM | 200NLPM | 320NLPM | 960NLPM |
Air flow rate | 200NLPM | 600NLPM | 950NLPM | 3100NLPM |
Internal volume | 500L | 1000L | 2000L | 3000L |
Internal dimensions (D*W*H) | 700mm*850mm*850mm | 1000mm*1000mm*1000mm | 1400mm*1200mm*1200mm | 1400mm*1300mm*1700mm |
External dimensions (D*W*H) | Nearly 1850mm*1230mm*2250mm | Nearly 2600mm*1300mm*2500mm | Nearly 2450mm*1450mm*2700mm | Nearly 3600mm*1750mm*2550mm |
Pressure relief port size | 0.06㎡ | 0.08㎡ | 0.12㎡ | 0.16㎡ |
Test hole | 1*Φ100mm | 1*Φ100mm | 1*Φ100mm | 1*Φ100mm |
Interface and quantity | Three in and three out DN25 quick fit SUS316 material (interface type and position size can be changed according to user needs) | |||
Gate | Single wing fully open door | |||
Load bearing capacity of the sample frame | 50Kg | 50Kg | 100Kg | 100Kg |
Installed power | 20Kw | 27Kw | 40Kw | |
Maximum current | 24A | 34A | 48A | |
Cooling water flow rate | 4m³/h | 6m³/h | 8m³/h | |
Interface type | External wire G1 | External wire G1 1/2 | ||
Weight | 800Kg | 1000Kg | 1500Kg | 2000Kg |
General Technical Indicators | ||||
Temperature range | -40℃~+90℃ | |||
Temperature rise and fall rate | ≥1℃min(unloaded, average throughout the entire process) | |||
Temperature fluctuation | ≤ ±0.5℃(static heat free cutting) | |||
Temperature deviation | ≤ ±2℃ (unloaded) | |||
Temperature uniformity | ≤2℃(unloaded) | |||
Humidity range | 20%RH~95% RH | |||
Humidity deviation | +2/-3.0% RH (humidity>75% RH) ± 5.0% RH (humidity ≤ 75% RH) |