6
6

Chambre de choc thermique (trois chambres)

Introduction
Adapted to determine the clean materials, electronics, electrical products, components and military equipment, etc. according to the national standard, military standard requirements when subjected to abrupt changes in the ambient air temperature (temperature shocks) when, whether to generate physical damage or performance degradation.

Fonctionnalité

  • 3 cases of equipment is divided into: high temperature, low temperature area, test area, test the product in the test area, impact at high temperature or low temperature zone temperature impact test area, test the product for static type.
  • The touch controller interface, operation easy.
  • Impact mode application wind path switching mode will import test temperature zone, cold and hot shock tests.
  • High temperature shock or the impact of low temperature and maximum time of up to 999 h, the maximum cycle of up to 9999 times.
  • System can make automatic cycle official holding or manual selective shock impact and can be set two areas or areas and cold heat impact and inception.
  • Cooling binary refrigeration system, cooling rapidly, for water-cooled cooling way.
  • Can perform impact test at room temperature to meet the standard and test method: GJB150.5 temperature impact test; GJB360.7 temperature impact test; GB / 2423.22 temperature impact test.
Chambre de choc thermique (trois chambres)
Modèle JTS72F-B/S/E JTS100F-B/S/E JTS150F-B/S/E JTS200F-B/S/E JTS320F-B/S/E JTS500F-B/S/E JTS1000F-B/S/E
Nominal inside volume(L) 72L 100L 150L 200L 320L 500L 1000L
Performance parameter Chambre de stockage de chaleur Plage d'exposition à la température +50℃~+150℃
Limite supérieure de température de préchauffage 200℃
Temps de chauffage RT~+200℃, B type: ≤50 min; S type: ≤40 min; E type: ≤30 min
Chambre froide Plage d'exposition à la température B type: 0~-40℃; S type: 0~-55℃; E type: 0~-65℃
Limite inférieure de température de pré-refroidissement -75 ℃
Temps de refroidissement RT~-70℃, B type: ≤60 min; S type: ≤50 min; E type: ≤40 min
Chambre Plage de choc thermique B type: -40℃~+150℃; S type: -55℃~+150℃; E type: -65℃~+150℃
Fluctuations de température ≤±0.5
Uniformité de la température ≤2℃
Écart de température ≤±2℃
Temps de transfert ≤10s
Temps de récupération de la température ≤5min
Charge (acier) 3kg 5 kg 7 kg 10 kg 15 kg 20 kg 40 kg
En option : fonction de test haute et basse température Plage de température -65 ℃ ~ + 150 ℃
Taux d'augmentation et de baisse de la température B type nearly 2℃/min, S type nearly 3℃/min, E nearly 4℃/min
Remarques Les indicateurs ci-dessus sont mesurés sans charge à une température ambiante de 20 ± 2 °C (selon GB/T 5170.2-2017).
Dimensions internes D 400 500 500 600 700 800 1000
W 450 500 600 600 700 900 1000
H 400 400 500 550 650 700 1000
Dimensions extérieures D 2150 2300 2300 2500 2600 2800 3600
W 1450 1500 1600 1600 1700 1900 2550
H 2000 2000 2200 2300 2500 2620 2250
Roulette 4 à 6 roulettes standards /
Trou d'essai Φ50 Φ100
Stainless steel shelf (2 pcs in standard configuration) Roulement 20 kg/pièce Roulement 30 kg/pièce Roulement 50 kg/pièce
Utilisation de la température ambiante 0 ~ + 40 ℃
Coquille Sprayed steel plate
Interior SUS 304 stainless steel
Mode refroidissement water-cooling, (water temperature 7~28℃, hydraulic pressure 0.2~0.4Mpa, to ensure cooling performance)
Contrôleur 7′ Color touch screen Controller
Fonction de communication Interface réseau RS485 ou RJ45 standard, interface USB standard
Capacité installée (kw) (L/S/E) 17/13/22 17/22/29 23/28/34 27/33/40 33/40/50 50/60/75 75/90/110
Weight(kg) 800 1300 1600 1900 2500 2800 3600
Découvrez la méthode de test GJB150.5-2009, GB/T2423-2008.
The optional high and low temperature test function also meets GB2423.1-2008, GB2423.2-2008, GJB150.3-2009, GJB150.4-2009.
Précautions de sécurité Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Heater short circuit protection, refrigeration unit overpressure/ overload/ oil shortage protection; Humidifier fault protection; Overload/ overheating protection for blower motor, overcurrent protection and leakage protection for control board; Cooling water shortage protection, gas source undervoltage protection, etc.
Facultatif 1.Optional high and low temperature testing function; 2. Optional special test holes and special shelves; 3. Optional liquid nitrogen function.